Main SP Tables-2

3.2 MAIN SP TABLES-2

3.2.1 SP2-XXX (DRUM)

[Charge DC Voltage]
2005
Adjusts the DC component of the charge roller bias in the print modes.
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
[Charge AC Voltage]
2006
Adjusts the AC component of the charge roller bias in the print modes.
001 Plain: Bk
002 Plain: C
003 Plain: M
004 Plain: Y
[Charge AC Current: LL]
2007
Displays/sets the AC current target of the charge roller for LL environment
(Low temperature and Low humidity).
001 Environmental Target: Bk
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y
2008
[Charge AC Current: ML]
D117/D118
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 1000 / 590 / 10 -V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 3000 / 2100 / 10V/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]
*ENG
[0 to 2000 / 600 / 10uA/step]