The default setting is "0" (OFF). This feature must be switched on in order for the
debug information to be saved.
4.
Select the target destination where the debug information will be saved. Under "5857 Save
Debug Log", touch "2 Target", enter "2" with the operation panel key to select the hard disk as
the target destination. Then press
Select "3 SD Card" to save the debug information directly to the SD card if it is
inserted in the service slot.
5.
Now touch "5858" and specify the events that you want to record in the debug log. SP5858
(Debug Save When) provides the following items for selection.
1
Engine SC Error
Controller SC Error
2
3
Any SC Error
Jam
4
SM
.
Saves data when an engine-related SC code is
generated.
Saves debug data when a controller-related SC
Code is generated.
Saves data only for the SC code that you
specify by entering code number.
Saves data for jams.
5-35
Using the Debug Log
D117/D118

Hide quick links: