002 Target(Lwr Limit)
Force Consume
005
Threshhold
006 Consume(Upp Limit)
007 Consume(Upp Limit)
008 Force Supply Threshhold
009 Supply(Upp Limit)
010 Supply(Lwr Limit)
021 Pattern Duty:K
022 Pattern Duty:C
023 Pattern Duty:M
024 Pattern Duty:Y
031 Max Counts:PowerON
034 Max Counts:Jobend
SM Appendix
Sets the lower limit of the target range of
developer gamma adjustment for toner
*ENG
density adjustment process control.
[0.00 to 1.00 / -0.15 /
0.01mg/cm^2/-kV/step]
Sets the forced consumption threshold for
toner density adjustment process control.
*ENG
[1.00 to 6.00 / 1.50 /
0.01mg/cm^2/-kV/step]
Sets the consumption pattern for toner
*ENG
density adjustment process control.
[10 to 2550 / 127 / 10cm^2/step]
Sets the upper limit of number of
consumptions for toner density
*ENG
adjustment process control.
[0 to 16 / 16 / 1times/step]
Sets the forced supply threshold for toner
density adjustment process control.
*ENG
[0.00 to 1.00 / 0.50 /
0.01mg/cm^2/-kV/step]
*ENG
Sets the upper or lower limit of supply
quantity for toner density adjustment
process control.
*ENG
[0.1 to 25.5 / 1.0 / 0.1g/step]
*ENG
Sets LD Duty of consumption pattern for
*ENG
toner density adjustment process control.
*ENG
[0 to 15 / 15 / 1/step]
*ENG
*ENG
Sets the upper limit of number of
consumptions for toner density
adjustment process control.
*ENG
[0 to 50 / 0 / 1/step]
3-235