Ricoh D117 Service Manual page 413

Hide thumbs Also See for D117:
Table of Contents

Advertisement

SC Tables
No.
Type
CTL
Self-diagnostic error: Standard SDRAM DIMM
835
B
[XXXX]: Detailed error code
Loopback connector is connected but check results in an error.
[1102]
1. Replace the controller board.
Loopback connector is connected but check results in an error.
[110C]
1. Replace the controller board.
Centronic loopback connector is not connected for detailed
self-diagnostic test.
[1120]
1. Replace the controller board.
No.
Type
CTL
Self-diagnostic Error: Clock Generator
838
D
[XXXX]: Detailed error code
A verify error occurred when setting data was read from the clock
generator via the I2C bus.
[2701]
1. Replace the controller board.
D117/D118
Details (Symptom, Possible Cause, Troubleshooting Procedures)
IEEE1284 connector error
Centronic loopback connector defective
ASIC device error
IEEE1284 connector error
Centronic loopback connector defective
Centronic loopback connector not connected correctly
Centronic loopback connector defective
ASIC device defective
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Defective clock generator
Defective I2C bus
Defective I2C port on the CPU