SC Tables
No.
Type
1. Turn the main switch off and on.
2. Reinstall the controller system firmware.
3. Replace the controller.
When the problem cannot be fixed with the above procedure, the
following information displayed on the screen needs to be fed back to a
technical support center.
- SC code
- Detailed error code
- Program address
CPU/Memory Error
[0701] to
[070A]
1. Reinstall the controller system software.
2. Replace the RAM-DIMM.
3. Replace the controller.
No.
Type
CTL
Self-diagnostics error: CPU
821
D
[XXXX]: Detailed error code
ASIC error
The write-&-verify check error has occurred in the ASIC.
[0B00]
1. Replace the controller board.
CPU/Memory Error
[0D05]
D117/D118
Details (Symptom, Possible Cause, Troubleshooting Procedures)
System firmware problem
Defective RAM-DIMM
Defective controller
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Defective ASIC device
System firmware problem
Defective RAM-DIMM
Defective controller