6. TROUBLESHOOTING

6.1 SC TABLES

6.1.1 SERVICE CALL CONDITIONS

Summary

The 'SC Table' section shows the SC codes for controller errors and other errors. The latter (not
controller errors) are put into four types. The type is determined by their reset procedures. The
table shows the classification of the SC codes.
Key
Controller
The error has occurred in the
CTL
errors
controller.
The error involves the fusing
unit. The machine operation is
A
disabled. The user cannot reset
the error.
The error involves one or some
specific units. The machine
B
operates as usual, excluding
the related units.
The error is logged. The
Other errors
SC-code history is updated.
C
The machine operates as
usual.
The machine operation is
disabled. You can reset the
machine by turning the
D
operation switch or main switch
off and on. If the error occurs
again, the same SC code is
displayed.
SM
Definition
See "Troubleshooting Procedure"
in the table.
Turn the main switch off and on.
Reset the SC (set SP5-810-1).
Turn the main switch off and on.
Turn the operation switch off and
on.
The SC will not show. Only the
SC history is updated.
Turn the operation switch or main
power switch off and on.
6-1