Tonersupply :Danc - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-3
072 Vt Integral Control: C
073 Vt Integral Control: M
074 Vt Integral Control: Y
081 Vt Integral Value: K
082 Vt Integral Value: C
083 Vt Integral Value: M
084 Vt Integral Value: Y
091 Vt Sum Times: K
092 Vt Sum Times: C
093 Vt Sum Times: M
094 Vt Sum Times: Y
3460

[TonerSupply :DANC]

011 Time_Min
012 Time_Max
022 SMITH_Unit_Weight
111 Rev_Fix:K
112 Rev_Fix:C
113 Rev_Fix:M
114 Rev_Fix:Y
121 N Delay:StdSpd
123 N Delay:LowSpd
D117/D118
*ENG
proportionate to the pixel (Pxl) of output
image at toner supply control.
*ENG
[0 to 2550 / 500 / 1/step]
*ENG
*ENG
Sets the supply coefficient to supply toner
*ENG
according to the accumulation of Vt-Vtref
differences at toner supply control.
*ENG
[-255.00 to 255.00 / 0.00 / 0.01/step]
*ENG
*ENG
Displays the accumulation of Vt-Vtref
*ENG
differences.
*ENG
[1 to 255 / - / 1times/step]
*ENG
Sets the DANC minimum supply time.
*ENG
[0 to 250 / 100 / 1msec/step]
Sets the DANC maximum supply time.
*ENG
[0 to 1000 / 200 / 1msec/step]
Sets the supply quantity at Smith model.
*ENG
[0 to 500 / 129 / 1mg/step]
*ENG
Sets the inverse of transfer rate to make
*ENG
up for the reverse transfer of ANC.
*ENG
[1.000 to 1.500 / 1.000 / 0.001/step]
*ENG
*ENG
Sets the delay time with the number of
control samplings from entrance of toner
supply of the Smith model to sensor.
*ENG
[0 to 200 / 3 / 1/step]
3-214
SM Appendix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D118Mp c305spMp c305spf