6.3.17 IMAGE SKEW
Symptom
Images are skewed
D117/D118
Possible cause
Incorrect installation of
paper
Incorrect paper guide
position
Defective registration roller
Incorrect action of paper
transfer roller
Defective BICU
Incorrect installation of
paper tray
6-96
Necessary actions
Install the paper correctly.
Adjust the paper guide
correctly.
When adjusting the
paper width, use
the right side guide
only, with the green
clip. Do not hold
the left side guide
at this time, or skew
will occur.
Repair the paper feed unit.
Check the paper transfer
roller.
Replace the BICU.
Uninstall the paper tray units
and re-install them.