Charge Output Control; Environmental Correction: Pcu - Ricoh D117 Service Manual

Hide thumbs Also See for D117:
Table of Contents

Advertisement

Main SP Tables-2
002 Environmental Target: C
003 Environmental Target: M
004 Environmental Target: Y

[Charge Output Control]

2012
Selects the AC voltage control type.
001 AC Voltage
2013

[Environmental Correction: PCU]

Current Environmental:
001
Display
002 Forced Setting
Absolute Humidity:
003
Threshold 1
Absolute Humidity:
004
Threshold 2
D117/D118
*ENG
[0 to 2000 / 650 / 10uA/step]
*ENG
[0 to 2000 / 650 / 10uA/step]
*ENG
[0 to 2000 / 650 / 10uA/step]
*ENG
[0 or 1 / 0 / 1/step]
Displays the environmental condition,
which is measured in absolute
humidity.
[0 to 5 / - / 1/step]
*ENG
1: LL (LL <= 4.3 g/m
2: ML (4.3 < ML <= 11.3 g/m
3: MM (11.3 < MM <= 18.0 g/m
4: MH (18.0 < MH <= 24.0 g/m
5: HH (24.0 g/m
Selects the environmental condition
manually. DFU
[0 to 5 / 0 / 1/step]
*ENG
0: The environmental condition is
determined automatically.
1: LL, 2: ML, 3: MM, 4: MH, 5: HH
Changes the humidity threshold
between LL and ML. DFU
*ENG
[0.00 to 100.00 / 4.30 / 0.01
3
g/m
/step]
Changes the humidity threshold
between ML and MM. DFU
*ENG
[0.00 to 100.00 / 11.30 / 0.01
3
g/m
/step]
3-68
3
)
3
)
3
)
3
)
3
< HH)
SM Appendix

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D118Mp c305spMp c305spf