Main SP Tables-3
021 Initial:K
022 Initial:C
023 Initial:M
024 Initial:Y
031 Env Cor.(ON/OFF)
032 TC Cor.(ON/OFF)
041 Environ Corr:K
042 Environ Corr:Col
051 TnrDensity Corr:K
052 TnrDensity Corr:C
053 TnrDensity Corr:M
054 TnrDensity Corr:Y
061 TnrDensity:K
062 TnrDensity:C
063 TnrDensity:M
064 TnrDensity:Y
071 Environ Corr1:Bk
072 Environ Corr2:Bk
D117/D118
*ENG
Sets the initial value of developer
*ENG
gamma.
[0.50 to 2.55 / 0.90 /
*ENG
0.01mg/cm^2/-kV/step]
*ENG
Sets on/off of developer gamma
(environment correction).
*ENG
[0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
Sets on/off of developer gamma (elapsed
time correction).
*ENG
0 or 1 / 1:ON / 1/step]
0:OFF, 1:ON
*ENG
Displays the environment correction of
developer gamma.
*ENG
[-1.00 to 1.00 / - / 0.01mg/cm^2/-kV/step]
*ENG
Displays the toner density correction of
*ENG
developer gamma.
*ENG
[-1.00 to 1.00 / - / 0.01mg/cm^2/-kV/step]
*ENG
*ENG
Displays the toner density calculated with
*ENG
TD sensor output.
*ENG
[0.0 to 25.5 / - / 0.1wt%/-kV/step]
*ENG
Sets the table value for environment
correction of developer gamma.
*ENG
[-1.00 to 1.00 / 0.00 / 0.01 mg/cm^2/-kV
/step]
[-1.00 to 1.00 / 0.04 /
*ENG
0.01mg/cm^2/-kV/step]
3-240