Engine start up error
The BICU fails to respond within the prescribed time when the machine
is turned on.
CTL
670
Connections between BICU and controller board are loose,
D
disconnected, or damaged.
1. Replace the BICU.
2. Replace the controller board.
No.
Type
Details (Symptom, Possible Cause, Troubleshooting Procedures)
Controller start up error
After the machine is powered on, the communication between the
controller and the operation panel is not established, or communication
with the controller is interrupted after a normal startup.
After startup reset of the operation panel, the attention code (FDH) or
the attention acknowledge code (FEH) is not sent from the controller
within 30 seconds.
After the controller issues a command to check the communication line
with the controller at 30-second intervals, the controller fails to respond
CTL
672
twice.
D
Controller stalled
Controller board installed incorrectly
Controller board defective
Operation panel connector loose or defective
The controller is not completely shut down when the main switch is
turned off.
1. Check the setting of SP5-875-001. If the setting is set to "1 (OFF)",
change it to "0 (ON)".
SM
6-43
SC Tables
D117/D118