Log Utilities - Toshiba 650CT Maintenance Manual

Hide thumbs Also See for 650CT:
Table of Contents

Advertisement

3.21 Log Utilities

3.21.1
Function Description
This function logs error information generated while a test is in progress and stores the
results in RAM. This function can store data on a floppy disk or output the data to a printer.
If the power switch is turned off, the error information will be lost. Error information is
displayed in the following order:
1.
Error count (CNT)
2.
Test name (TS-NAME)
3.
Subtest number (TS-NAME)
4.
Pass count (PASS)
5.
Error status (STS)
6.
FDD/HDD or memory address (ADDR)
7.
Write data (WD)
8.
Read data (RD)
9.
HDC status (HSTS)
10.
Error status name ( ERROR STATUS NAME)
3.21.2
Operations
1.
Selecting 5 and pressing Enter in the DIAGNOSTIC MENU logs error
information into RAM or onto a floppy disk. The error information is
displayed in the following format:
XXXXX ERRORS
CNT TS-NAME PASS STS ADDR
001 FDD 02
001 FDD 01
Test name
Error count
[[1:Next,2:Prev,3:Exit,4:Clear,5:Print,6:FD Log Read,7:FD Log Write]]
3-44
0000 103 00001
0000 180 00001
Address
Error status
Pass count
Subtest number
WD RD HSTS [STATUS NAME]
00 00
FDD - WRITE PROTECTED
00 00
FDD - TIME OUT ERROR
HDC status
Read data
Write data
Error status name
650CT