Procedure 3
Connector Check
The display unit has an LCD module, FL, display switch, and FL inverter board. The FL and
FL inverter board are connected by two cables, and the LCD module and system board are
connected by one signal cable as shown below. Any of these cables may be disconnected.
Disassemble the display unit and check the following cable connections. Refer to Chapter 4,
Replacement Procedures, for more information about how to disassemble the computer.
Figure 2-3 Display connection
If any of these cables is not connected, firmly reconnect it and repeat Procedures 1 and 2. If
the problem still exists, perform Procedure 4.