Check 3
If error code 03h displays:
Make sure the Desk Station V Plus or Enhanced Port Replicator II is firmly
connected to the computer's docking interface port. If this port is connected
correctly, go to the following step.
Visually check the connector to make sure no pins are bent. If a pin(s) is bent,
go to Chapter 4, Replacement Procedures. If the connector is not physically
damaged, go to the following step.
Check the Desk Station V Plus or Enhanced Port Replicator II for malfunc-
tions. Refer to the Desk Station V Plus Maintenance Manual for details.
If the error still exists, go to Procedure 5.
Check 4
If error code 10h displays:
Make sure the battery pack is correctly installed in the computer.
If the battery pack is correctly installed, go to the following step.
Replace the battery pack with a new one.
If the error still exists, go to Procedure 5.
Check 5
When 80h is displayed, it indicates that the CPU temperature is outside the
allowable operating range. Perform the following steps:
Leave the computer in an area that is about room temperature until the CPU's
internal temperature is within the allowable operating range.
If the error still exists, go to Procedure 5.
Check 6
When 88h is displayed, it indicates that the CPU temperature is too high. In this
case, the computer automatically enters resume mode and shuts down.
Leave the computer off until the DC IN icon stops blinking. It is recom-
mended to leave the computer off until its interior reaches room temperature
even though the DC IN icon stops blinking.
If the error still exists, go to Procedure 5.
Check 7
For any other error, go to Procedure 5.