Toshiba 650CT Maintenance Manual page 59

Hide thumbs Also See for 650CT:
Table of Contents

Advertisement

NOTE: The menu displayed by your computer may be slightly different from
the one shown above.
4.
Select the desired subtest number from the subtest menu and press Enter.
The following message will appear:
TEST LOOP
ERROR STOP : YES
Selecting YES for TEST LOOP sets the test to run continuously until it is halted
by the user. Selecting NO returns the screen to the main menu after the test is
complete.
Selecting YES for ERROR STOP stops the test program when an error is found
and displays the operation guide on the right side of the display screen as shown
below:
ERROR STATUS NAME
These three selections have the following functions:
1:
Terminates the test program and exits to the subtest menu.
2:
Continues the test.
3:
Restarts the test from the error.
Use the arrow keys to move the cursor to the desired option and press Enter.
Selecting NO for ERROR STOP keeps the test running even if an error is found.
Table 3-1 in Section 3.3 describes the function of each test on the subtest menu. Table 3-2 in
Section 3.18 lists the error codes and error status for each error.
650CT
: YES
[[ HALT OPERATION ]]
1: Test end
2: Continue
3: Retry
3-5