Sign In
Upload
Manuals
Brands
CareFusion Manuals
Fan
AVEA
CareFusion AVEA Manuals
Manuals and User Guides for CareFusion AVEA. We have
2
CareFusion AVEA manuals available for free PDF download: Operating Instructions Manual, Quick Tips
CareFusion AVEA Operating Instructions Manual (263 pages)
Brand:
CareFusion
| Category:
Fan
| Size: 11.21 MB
Table of Contents
Table of Contents
5
EMC Notice
7
Intended Use Notice
7
MRI Notice
7
Regulatory Notice
7
Classification
8
Safety Information
9
Terms
9
Warnings
9
Cautions
10
Equipment Symbols
11
Chapter 1: Introduction
15
Functions & Accessories
15
Artificial Airway Compensation
16
Features
16
Circuit Compliance Compensation
17
Full Range of Patient Size
17
Leak Compensation
17
Non-Invasive Ventilation
17
Heliox Delivery (Comprehensive Only, Option on Standard)
18
Humidification
18
Air or Heliox Supply
21
Chapter 2: Unpacking & Setup
21
Ventilator Assembly & Physical Setup
21
Assembling the Ventilator
22
Setting up the Front of the Ventilator
23
Assembling the Exhalation Filter and Water Trap
23
External Battery Option
23
Disposable Expiratory Filter / Water Trap
26
User Instructions
26
Additional Information
29
Attaching the Patient Circuit
30
Adult Circuit Using an Active Humidifier
30
Adult Circuit Without Active Humidifier
30
Neonatal Patient Circuit
31
Front Panel Connections
31
Attaching Flow Sensors
32
Hot Wire Flow Sensor
32
Hot Wire Flow Sensor Zero Procedure
33
Variable Orifice Flow Sensor
34
Attaching a Nebulizer
35
Attaching a Proximal Pressure Sensor
36
Esophageal Balloon
37
Tracheal Catheter
37
Setting up the Rear of the Ventilator
38
Connecting the Oxygen Sensor
39
Connecting Gas Fittings
39
The “Smart” Air Fitting
39
The “Smart” Heliox Fitting
40
Attaching the Gas Hoses
40
Oxygen Connection
40
Heliox Connection
40
Attaching the Air Hose
41
Utilities Screens
42
Configuration Tab
42
Alarm Loudness
42
Enable / Disable O2 Alarm
42
Flow Correction
43
ILV Mode
43
Setting up Independent Lung Ventilation (ILV)
43
ILV Connector Pin Configuration
44
Analog Ground Pins View
44
Selecting Language
45
Low Vte Alarm Sensitivity
45
Increase F IO2
45
Input/Output Tab
46
Analog Input Configuration
47
Analog Input Connections
47
Analog Outputs
48
Set Analog Output Type
48
Analog Outputs Pin Configuration
48
RS 232 Output
49
ILV and Analog I/O Pin Configuration
49
Vuelink
50
Nurse Call Connection
51
Date/Time Tab
51
Setting the Date
51
Setting the Time
51
Powering up the AVEA
52
User Verification Test
53
The Power on Self Test (POST)
53
The Extended Systems Test (EST)
54
The Alarms Test
55
Default Settings for Adult, Pediatric and Neonate
57
Ventilation Setup
57
Primary Controls
57
Advanced Settings
57
Alarm Settings
58
Auxiliary Controls
58
AVEA User Verification Test Checklist
59
AVEA Troubleshooting
60
Membrane Buttons and Leds
65
User Interface Module (International) Showing Button Icons
65
Items Required for Ventilator Setup
21
Oxygen Supply
21
Unpacking and Setup
21
Chapter 3: Ventilator Operation
65
Alarm Reset
66
Alarm Silence (LED)
66
User Interface Module (English) Showing Button Labels
66
Alarm Limits
67
Increase O2
67
Manual Breath
67
Suction (LED)
67
Accept
68
Cancel
68
Data Dial
68
Expiratory Hold
69
Inspiratory Hold (Manual)
69
Nebulizer
69
Patient Size
69
Advanced Settings (Led)/Mode/Event
70
Panel Lock (LED)
70
Print
70
Set-Up
70
Flow/Volume Loop in Freeze Mode
71
T. Freeze
71
Alarm Status Leds
72
Main
72
Screens
72
Screens Selection Box View
72
Patient Select Screen
73
Patient Setup
73
Patient Size Select Screen
74
Artificial Airway Compensation (AAC)
75
Ventilation Setup Screen View
75
Circuit Compliance
76
Leak Compensation (LEAK COMP)
76
Humidifier
77
Identification
77
Patient Weight
77
EST (Extended Systems Test)
78
Adult and Pediatric Mode Select Screen
80
Infant Mode Select Screen
80
Setting the Ventilation Breath Type and Mode
80
Breath Types
81
Flow Cycle/Volume Limit
81
Specific Controls
81
Volume Guarantee (VG)
81
Delivered Pressure
82
Inspiratory Pressure
82
Machine Volume
82
Volume Target
82
Alarms and Safety Systems
83
High Ppeak
83
Low Ppeak
83
Wye Sensor Disconnect
83
Alarm Activation
84
Limit Volume
84
Low Expired Volume
84
Initiating Volume Guarantee
85
Messages
86
Troubleshooting
87
Mandatory Breaths
88
The Intra-Breath Demand System in Volume Ventilation
88
Volume Breaths
88
Pressure Breaths
89
Pressure Regulated Volume Control (PRVC)
89
Time Cycled Pressure Limited (TCPL)
89
Demand Breaths
90
PSV (Pressure Support Ventilation)
90
Spontaneous Breath
91
Assist Control Ventilation (A/C)
92
Ventilation Modes
92
SIMV Waveform
93
Synchronized Intermittent Mandatory Ventilation (SIMV)
93
Adjustable PSV in APRV / Biphasic
94
Airway Pressure Release Ventilation (APRV / BIPHASIC)
94
Apnea Ventilation in APRV / Biphasic
95
APRV / BIPHASIC Mode
95
CPAP Waveform
96
Apnea Backup in Assist Control or SIMV
97
Apnea Backup Ventilation
97
PSV Waveform
97
Apnea Backup in CPAP/PSV or APRV / BIPHASIC
98
Pressure Apnea Backup Settings for APRV / BIPHASIC Mode
99
Volume Apnea Backup Settings for CPAP Mode
99
Pressure Apnea Backup Settings for CPAP Mode
100
Screen Select
101
Standby
101
Standby Message
101
Standby Screen
102
Adult and Pediatric Ventilation Modes
103
Available Breath Types & Modes by Patient Size
103
Neonatal Ventilation Modes
103
Primary Breath Controls
104
Breath Rate (Rate)
106
Descriptions of Primary Breath Controls
106
Inspiratory Pressure (Insp Pres)
106
Tidal Volume (Volume)
106
Inspiratory Pause (Insp Pause)
107
Inspiratory Time (I-Time)
107
Peak Flow
107
PSV (Pressure Support)
107
Positive End Expiratory Pressure (PEEP)
108
Inspiratory Flow Trigger (Flow Trig)
109
Pressure High (Pres High)
109
Time High
109
Accessing the Advanced Settings
110
Advanced Settings Indicator View
110
Pressure Low
110
Time Low
110
Controls and Advanced Settings Associated with Breath Type & Mode
111
Advanced Settings Characteristics and Ranges
112
Volume Limit (Vol Limit)
112
Machine Volume (Mach Vol)
113
Demand Flow
114
Flow Cycle
114
Insp Rise
114
Waveform
114
Bias Flow
115
Pres Trig
115
Sigh
115
Vsync
115
PSV Rise
116
Vsync Rise
116
PSV Cycle
117
PSV Tmax
117
T High PSV/T Low Sync
117
T High Sync
117
Independent Lung Ventilation (ILV)
118
Graphic Displays
119
Graphics Colors
119
Waveforms
119
Chapter 4: Monitors, Displays and Maneuvers
119
Waveform Selection
120
Axis Ranges
121
Time Ranges
121
Waveform Choices
121
Accessing the Loops Screen
122
Choice of Loops
122
Loops
122
Creating a Reference Loop
123
Saving a Loop
123
Using the Freeze Button to Compare Loops
123
Maneuvers
124
Controls
125
Esophageal Maneuver Screen
125
Balloon Fill Start / Stop
126
Balloon Leak / Size Test
126
Selecting Balloon Size and Type
126
Alarms
127
Chest Wall Compliance (C Cw)
127
To Perform Esophageal Maneuvers
127
Duration
129
MIP / 100 Pmaneuver Screen
129
MIP Maneuver Settings
129
Sensitivity
130
Start / Stop
130
Inflection Point (Pflex) Maneuver Screen
131
Pflex Maneuver Settings
131
Maneuver PEEP (PEEP)
132
PEEP Equilibration Time (PEEP Teq)
132
Upper Pflex and Lower Pflex Determination
133
Autopeep Maneuver Screen
135
To Perform an Autopeep Maneuver
136
Capnometry Screen
137
Tracheal Catheter Placement
137
Digital Displays
138
The Monitor Screen
138
Monitored Values Menu Choices
139
Events
142
Trends
143
Calculated I:E Ratio
144
Calculated Minute Volume (Calc Ve)
144
Calculated Time High & Time Low Min / Max
144
Main Screen Displays
144
Calculated Time High: Time Low Ratio
145
Main Screen Monitors
146
Chapter 5: Volumetric Capnography
147
Theory of Operation
147
Setup (Volumetric Capnography)
148
Adult / Pediatric Adapter View
150
Pediatric / Neonatal Adapter View
150
Settings and Monitored Values
151
Capnography – Enable / Disable
151
Etco2 Averaging
151
Vco2 Averaging
151
Monitored Values
152
Zero Co2/Calibration Check
152
End Tidal CO2 (Etco2)
152
CO2 Elimination (VCO2)
152
CO2 (Vtco2)
153
Anatomical Dead Space (VD Ana)
153
Anatomical Dead Space / Tidal Volume Ratio (VD / Vt Ana)
153
Alveolar Ventilation (Va)/Physiologic Dead Space (VD Phy)
153
Physiologic Dead Space / Tidal Volume Ratio (VD / Vt Phy)
154
Alveolar Dead Space (VD Alv)/Oxygenation Index (OI)
154
Waveforms and Loops
154
PCO2 Wave (Capnogram)/Pco2/ Vte Loop
154
Capnometry Alarms
155
High Etco2
155
Low Etco2
155
Maneuvers (Volumetric Capnography)
156
Event Softkey
156
Capnometry in Maneuver Screen View
157
Zeroing the CAPNOSTAT 5
158
Bottom of AVEA UIM View
158
Zero CO2 Sensor Message
159
Checking the Accuracy of the CAPNOSTAT 5
160
Bottom of UIM View
160
Configuration Tab in Utility Screen View
161
CO2 Calibration Message
161
Nasal CPAP (Ncpap)
163
Circuit Compatibility
163
General Specifications (Ncpap)
163
Chapter 6: Infant Non-Invasive Ventilation
163
High Ncpap Pressure
164
Initiating Nasal CPAP
164
Low Ncpap Pressure
164
Ncpap Pressure Limit
164
Calibration Required Message
165
Disconnect Point for Calibration
165
Mode Selection
165
Calibration Progress Message
166
Calibration Successfully Completed Screen
166
Caution Message Display (Ncap)
167
Monitors
167
Ncpap Primary Controls and Alarm Threshold Indicators
167
Displayed Waves
168
Graphics
168
Circuit Compatibility (Nimv)
169
General Specifications (Nimv)
169
Nasal Intermittent Mandatory Ventilation (Nimv)
169
Insp Press/Insp Rise
170
Insp Time
170
Ncpap Flow
170
Rate
170
Alarms Suspended During Ncpap with Rate Set to off
171
Ncpap/IMV Disconnect Sensitivity
172
Initiating Nasal CPAP / NIMV
174
Monitors (Nasal CPAP)
177
Displayed Waveforms (Nasal CPAP)
178
Graphics (Nasal CPAP)
178
Messages (Nasal CPAP)
179
Troubleshooting (Nasal CPAP)
179
Compressor Active/Heliox Source Connected
181
Mains/Battery Indicators
181
Status Indicators
181
Chapter 7: Alarms and Indicators
181
Battery Status Indicators
182
Internal Battery Power Indicator
182
The Message Bar
183
“Popup” Alert Messages
183
Alarm Categories
184
High Priority (Warning)
184
Low Priority (Advisory)/Backup Alarm (Advisory)
184
Medium Priority (Caution)
184
Alarm Controls
185
Setting an Alarm Limit
185
Alarm Silence/Alarm Reset
186
Alarm Types
186
Machine Alarms
186
Safety Valve Open/Ventilator Inoperative/Not Ventilating
186
Fan Failure Alarm/Circuit Disconnect Alarm
187
Gas Supply Indicators and Alarms
187
Loss of Air Alarm
187
Loss of O 2 Alarm/Loss of Gas Supply Alarm
187
High Peak Pressure Alarm
188
Loss of Heliox Alarm
188
Low Peak Pressure Alarm
188
Pressure Alarms
188
Circuit Occlusion Alarm
189
Extended High Peak Pressure Alarm
189
Low PEEP Alarm
189
High Exhaled Minute Volume (High Ve)
190
Low Exhaled Minute Volume (Low Ve)
190
Low Exhaled Tidal Volume (Low Vt)
190
Volume Alarms
190
Apnea Interval/High Rate/I:e Ratio Limit (I:E Limit) Alarm
191
High Tidal Volume (High Vt)
191
Maximum Inspiratory Time Limit (Max I-Time) Alarm
191
Rate/Time Alarms
191
O2 Alarms
192
Nasal CPAP / Nasal IMV Alarms
195
Volume Guarantee Alarms
198
Cleaning and Sterilization
201
Limitations on Reprocessing
201
Manual Cleaning
201
Chapter 8: Maintenance and Cleaning
201
Capnometry Airway Adapters
202
Cleaning the Outside of the Capnometry Sensor and Cable
202
Sterilization
202
Additional Information on Cleaning
203
Recommended Periodic Maintenance
204
Battery Care
205
Internal Battery Pack View
205
Precedence of Power Use
206
Battery Status
207
Failure to Charge the Battery
207
Battery Fuses
208
External Battery Connector & Fuse View
208
Operator's Manual
208
Mains Fuses
209
Replacing a Mains Electrical Fuse
209
Appendix A: Contact & Ordering Information
211
How to Call for Service
211
Ordering Parts
212
Pneumatic Supply Specifications
215
Electrical Supply Specifications
215
AC Power Supply Specifications
215
Air or Heliox Supply Specifications/Oxygen Supply Specifications
215
Appendix B: Specifications
215
Data Input / Output Specifications
216
DC Power Supply Specifications
216
Independent Lung Ventilation (ILV) Specifications
216
Analog Inputs Data
217
Analog Outputs Data
217
Breath Phase Data
218
Volume Data
218
Digital Communication
219
VOXP (Ventilator Open XML Protocol)
221
Atmospheric & Environmental Specifications
222
Remote Nurse Call
222
Temperature and Humidity Data
222
VOXP Communications Requirements
222
Accessories
223
Barometric Pressure
223
Pall Microbial Filter Data/Water Trap Data
223
Physical Dimensions
223
AVEA Disposable Expiratory Filter / Water Trap Specifications
224
Gas Delivery Engine
225
Appendix C: Pneumatic Diagram
225
Appendix D: Monitor Ranges and Accuracies
227
Appendix E: Sensor Specifications & Circuit Resistance
231
Varflex ® Sensor Specifications
231
Hot Wire Flow Sensor Specifications
232
Circuit Resistance Test
233
Volumetric Capnography Specifications
234
Appendix F: AVEA Message Bar Text
235
Appendix G: Advanced Pulmonary Mechanics Monitored Parameters
237
Chest Wall Compliance (Ccw)
237
Lung Compliance (Clung)
237
Rapid Shallow Breathing Index (F / Vt)
237
Compliance Ratio (C20/C)
238
Peak Expiratory Resistance (Rpeak)
238
Respiratory System Resistance (Rrs)
238
Imposed Resistance (Rimp)
239
Lung Resistance (Rlung)
239
Peak Expiratory Flow Rate (PEFR)
239
Peak Inspiratory Flow Rate (PIFR)
239
Autopeepaw
240
Delta Airway Pressure (Dpaw)
240
Delta Esophageal Pressure (Dpes)
240
Autopeepes
241
Delta Autopeepaw (Dautopeepaw)
241
Transpulmonary Pressure, Plateau (Ptp Plat)
241
Maximum Inspiratory Pressure (MIP)
242
Respiratory Drive (P100)
242
Transpulmonary Pressure, Autopeep (Ptp PEEP)
242
Patient Work of Breathing (Wobp)
243
Ventilator Work of Breathing (Wobv)
243
Imposed Work of Breathing (Wobi)
244
Appendix H: Capnometry Troubleshooting
245
Appendix I: Volumetric CO 2 Calculations
247
Volumetric CO2 Calculations
247
Anatomic Dead Space (VD Ana)
249
Alveolar Dead Space
250
Alveolar Ventilation (Va)
250
Anatomic Dead Space / Tidal Volume Ratio (VD Ana / Vt)
250
Oxygenation Index (OI)
250
Appendix I: Volumetric Cocalculations
251
Appendix J: Electromagnetic Declarations
251
Guidance and Manufacturer’s Declaration - Electromagnetic Immunity
252
Distance between RF Communications Equipment and AVEA Ventilator
254
Appendix K: Glossary
255
Index
257
Advertisement
CareFusion AVEA Quick Tips (8 pages)
Brand:
CareFusion
| Category:
Fan
| Size: 0.59 MB
Advertisement
Related Products
CareFusion Alaris TIVA
CareFusion Alaris GH
CareFusion Alaris
CareFusion Alaris VP Plus Guardrails
CareFusion Alaris Gateway Workstation
CareFusion Alaris GW
CareFusion Alaris DS
CareFusion Alaris Propofol-Paedfusor
CareFusion Alaris GP
CareFusion Alaris 8210 Series
CareFusion Categories
Medical Equipment
Measuring Instruments
Water Pump
Fan
Respiratory Product
More CareFusion Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL