Resetting Parameters To Factory Defaults - DURKOPP ADLER 512 Operating Instructions Manual

Hide thumbs Also See for 512:
Table of Contents

Advertisement

Settings via the software

5.20 Resetting parameters to factory defaults

Prerequisite:
• Machine is in programming mode, Ready button LED is off.
1. Press and hold the Memory button for 6 s.
 The button LED illuminates.
2. Use the +/– Program buttons to set parameter number U098.
3. Press the Ready button.
4. Use the +/– Function buttons to enter a function value of 1.
5. Press the Select button.
 The controller beeps once. If the controller beeps three times
then the reset was not successful.
6. For Class 532 set the parameter U085.
Setting parameter U085 (Class 532)
With the button sewing machine, parameter U085 must also be
adjusted after resetting the parameters to factory defaults.
Prerequisite:
Machine is in programming mode, Ready button LED is off.
1. Press and hold the Memory button for 6 s.
 The button LED illuminates.
2. Use the +/– Program buttons to set parameter number U085.
3. Press the Ready button.
4. Use the +/– Function buttons to enter a function value of 1.
 Press the Select button.
48
Operating Manual 512/532 Version 00.0 - 12/2013

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

532