Setting the needle bar
7.2 Angular position of the single-needle sewing machine
Proper setting
The angular position of the needle holder should be set depending on the
needle number as per the table:
Fig. 18: Angular position of the single-needle sewing machine needle holder
(1) - Groove
(2) - Screw
(3) - Needle holder
1. Remove the head cover ( p. 17).
2. Loosen the screw (2) and turn the needle bar so that the right end of
3. Tighten the screw (2).
4. Lock the machine in place at position 2 ( p. 21).
5. Insert the 2.5 mm Allen wrench into the opening (4) and loosen the
6. Turn the needle holder (3) to have the correct setting.
7. Tighten the fixing screw.
Service Instructions 878-M PREMIUM - 03.0 - 10/2019
needle holder
Needle holder displacement
Needle number
the groove (1) faces the needle bar axis.
fixing screw of the needle holder inside the needle bar.
70 – 110
120 – 160
(4) - Opening
(5) - 2.5 mm Alley wrench
180 – 200
29