E. Lens unit
Note: Do not remove screws which are not indicated in the figure. If the
height of the base plate is changed, it cannot be adjusted in the
market.
Note: The CCD/lens unit is factory-adjusted before shipping.
Since these adjustments cannot be performed in the market.
Never touch the screws other than screw 2) of the CCD/lens unit.
(2)
(1)
(1)
(2)
(3)
(4)

Lens unit attachment

<1>Attach the lens unit so that the lens unit number on the
lens adjustment plate is aligned with the scribe line on the
base plate.
+4 scales
+3 scales
+2 scales
+1 scale
Reference
-1 scale
-2 scales
-3 scales
-4 scales
<2>Make a sample copy at the above position, and measure
the magnification ratio.
<3>Change the installing position in the horizontal direction to
adjust the magnification ratio.
•When the copy image is longer than the original, shift to
the positive (+) direction.
•When the copy image is shorter than the original, shift to
the negative (-) direction.
*
1 scale of the scribed line corresponds to 0.34% of
magnification ratio.
*
If this adjustment is not satisfactory, make a fine adjustment
with SIM 48-2.
(1)
(3)
Lens unit number
( ) direction
Reference line (0)
(+) direction
One division: 1.4mm
CCD adjustment value
5.0~
3.6~4.9
2.2~3.5
0.8~2.1
-0.6~0.7
-2.0~ -0.7
-3.4~ -2.1
-4.8~ -3.5
~ -4.9
AR-M207 M165 M162 DISASSEMBLY AND ASSEMBLY 10-3
F. Wire
(1)
(4)
(2)
G. Document detection
For U.S.A.
(2)
(3)
(4)
(1)
(2)
For EU. Australia
(2)
(3)
(1)
(2)
(4)
(3)
(1)
(2)
(3)
(2)
(1)
(3)
(4)

Hide quick links: