Sharp AR-M207 Service Manual page 37

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
25
01
Main motor operation check (Cooling fan motor rotation
check)
10
Polygon motor operation check
26
01
Job separator setting
02
Size setting
03
Auditor setting
04
Copier duplex setting
05
Count mode setting
06
Destination setting
07
Machine condition check
18
Toner save mode setting
20
Job separator paper exit mode setting
22
Language setting clear
30
CE mark conformity control ON/OFF
31
Auditor mode exclusive setup
36
Cancel of stop at maintenance life over
37
Cancel of stop at developer life over
39
Memory capacity check
42
Transfer ON/OFF timing control setting
43
Side void amount setting
51
Copy temporary stop function setting
54
LCD contrast PWM duty setting
60
FAX mode key Enable/Disable setting
73
Toner save setting display/non-display
74
Total counter display change setting
30
01
Paper sensor status display
41
01
Document size detection photo sensor check
02
Document size detection photo sensor detection level
adjustment
03
Document size detection photo sensor light receiving/
detection level check
04
Detection level adjustment when the document size is
settled(15degrees - 20degrees)
42
01
Developing counter clear
43
01
Fusing temperature setting (Normal copy)
12
Standby mode fusing fan rotation setting
13
Fusing paper interval control allow/inhibit setting
44
34
Transfer current setting
40
Setting of rotation time before toner supply
46
01
Copy density adjustment (300dpi)
02
Copy density adjustment (600dpi)
09
Copy exposure level adjustment, individual setting
(Text) 300dpi
10
Copy exposure level adjustment, individual setting
(Text) 600dpi
11
Copy exposure level adjustment, individual setting
(Photo) 600dpi
18
Image contrast adjustment (300dpi)
19
Exposure mode setting
(Gamma table setting/AE operation mode setting/
Photo image process setting)
20
SPF exposure correction *2
29
Image contrast adjustment (600dpi)
30
AE limit setting
31
Image sharpness adjustment
48
01
Main/sub scanning magnification ratio adjustment
05
SPF/RSPF mode sub scanning magnification ratio
adjustment in copying *2
49
01
Flash ROM program writing mode
Contents
AR-M207 M165 M162 SIMULATIONS 7-2
Main
Sub
code
code
50
01
Image lead edge adjustment
06
Copy lead edge position adjustment (SPF/RSPF) *2
10
Paper off-center adjustment
12
Document off-center adjustment
18
Memory reverse position adjustment in duplex copy *1
19
Rear edge void adjustment in duplex copy *6
51
02
Resist amount adjustment
53
08
SPF scanning position automatic adjustment *2
10
SPF scanning position setting
61
03
HSYNC output check
63
01
Shading check
07
SPF automatic correction *2
64
01
Self print
65
10
Key reception time setting display/non-display setting
11
Info lamp setting
67
50
USB reception speed adjustment
<Execution inhibit conditions>
*1) Execution is inhibited when the duplex setup is OFF and other than
RSPF is set.
*2) Execution is inhibited when OC.
*3) Execution is inhibited when SPF. (Not RSPF)
*4) Execution is inhibited when the job separator is not installed.