Fusing Lamp And Cooling Fan Operation Check; Copy Lamp Lighting Check; Paper Feed/Transport Solenoid Operation Check; Resist Roller Solenoid (Rrs) Operation Check - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
05
02

Fusing lamp and cooling fan operation check

Used to check the operations of the heater lamp and the cooling fan and the peripheral circuits.
When this simulation is executed, the following initial menu is displayed.
(Initial window)
Sim5-2
PRESS OK KEY EXEC
When this simulation is executed, the fusing lamp repeats ON/OFF 5 times in the cycle of 500ms.
The cooling fan motor is rotated during that period. (The cooling fan, however, is rotated for about 8sec.)
After completion of the operation, the machine returns to the sub code input window.
03

Copy lamp lighting check

Used to check the operations of the copy lamp and its peripheral circuit.
When this simulation is executed, the following initial menu is displayed.
(Initial window)
Sim5-3 COPY LAMP
PRESS OK KEY EXEC
When [OK] key or [START] key is pressed, the copy lamp is lighted for about 5sec.
After passing for 5sec, the machine returns to the sub code input window.
06
01

Paper feed/transport solenoid operation check

When this simulation is executed, the names of the solenoids which can be operated are displayed. Select a
load to be operated with the 10-key.
(Load selection window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
1/2
EXEC
(Load selection window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
1/2
EXEC
OK/START Key
(Execution window)
Sim6-1 OUTPUT CHECK
1:CPSOL
2:PSOL1
3:PSOL2
1/2
EXEC
02

Resist roller solenoid (RRS) operation check

When this simulation is executed, the machine goes to the execution start window. When [OK] key or
[START] key is pressed, the resist roller solenoid (RRS) repeats ON of 500ms and OFF of 500ms 20 times.
(Execution start window)
Sim6-2 RRS CHECK
PRESS OK KEY EXEC
When the operation is completed, the machine returns to the sub code input window.
When [Interruption] key is pressed, the machine returns to the sub code input window. When [CA] key is
pressed, the machine exits the simulation mode.
(Execution window)
HT LAMP
OK/START Key
(Execution window)
OK/START Key
4:PSOL3
5:HPSOL
1: CPSOL
6:FSOL2
2: PSOL1
1
3: PSOL2
4: PSOL3
10Key
5: HPSOL
6: FSOL2
7: FSOL3
(*) Supported only for the model with the option installed.
4:PSOL3
Skipped for the other models without installation.
5:HPSOL
6:FSOL2
After completion
2
of execution
During execution, the selected solenoid repeats
4:PSOL3
ON/OFF 20 times for every 500ms.
5:HPSOL
6:FSOL2
2
(Execution window)
OK/START Key
AR-M207 M165 M162 SIMULATIONS 7-8
Contents
Sim5-2
HT LAMP
EXEC
Sim5-3 COPY LAMP
EXEC
:Cassette 1 paper feed solenoid
:Cassette 2 paper feed solenoid (*)
:Cassette 2 paper feed solenoid (*)
:Cassette 3 paper feed solenoid (*)
:Manual feed tray paper feed solenoid
:Cassette 2 transport solenoid (*)
:Cassette 3 transport solenoid (*)
Sim6-2 RRS CHECK
EXEC
Remark

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ar-m165Ar-m162

Table of Contents