48
01

Main/sub scanning magnification ratio adjustment

Used to adjust the magnification ratio in the main scanning (front/rear) direction and the sub scanning
direction.
When this simulation is executed, the selection window of the adjustment items and the current set value
are displayed
(Adjustment item selection window)
Sim48-1 COPY MAG.
1:F-R
2:SCAN
[
The adjustment value is in the range of 1 - 99. (Default: 50).
When the adjustment value is increased by 1, the ratio is increased by 0.1%.
Select an adjustment item (mode) with the cross key and enter a desired value with 10-key.
When [OK] key is pressed, the entered value is saved to the EEPROM and the machine shifts to the copy
execution window.
After completion of copying, the machine returns to the adjustment value input window.
When [START] key is pressed instead of [OK] key, the machine shifts to the copy execution window and
performs copying.
(Copy start window)
Ready to copy.
S
100%
8 1/2 11
(Copy execution window)
Copies in progress.
S
100%
8 1/2 11
Display text array
50
1: F-R
50
2: SCAN
1- 99]
50
AR-M207 M165 M162 SIMULATIONS 7-36
Contents
: Adjustment mode
: Main scan direction magnification
ratio (OC/CR)SPF)
: Sub scan direction magnification ratio (OC)