25
10

Polygon motor operation check

When [OK] or [START] is pressed, the polygon motor is rotated for 30sec.
(Execution start window)
Sim25-10 LSU CHECK
PRESS OK KEY EXEC
After completion of the process, the machine shifts to the sub code input window.
[CA] key: Exits the simulation mode.
[Interruption] key: Interrupts the output operation, and shifts to the sub code input window.
26
01

Job separator setting

Used to set YES/NO of installation of the hob separator.
After installation of the job separator, setting must be manually set to YES.
Sim26-1 JBS SET
1:JOB SEPARATOR
0=NONE
1=SEPARATOR
[ 0-1]
[CA] key: Exits the simulation mode. (When setting is changed, the machine exits the simulation mode and
performs the hard reset.)
[Interruption] key: Shifts to the sub code input window. (When setting is changed, it is invalid.)
[START] key: Setting contents are saved in the EEPROM and the machine shifts to the code input window.
02

Size setting

Used to set Enable/Disable of FC (8.5" x 13") size detection.
Detection size when FC (8.5" x 13") size document is used.
Document
* For destinations other than the above, this setting is invalid.
Sim26-2 SIZE SET
1:B4/LG,FC
0=B4/LG
1=FC
[ 0-1]
03

Auditor setting

Used to set the auditor.
Sim26-3 AUDITOR SET
1:AUDITOR
0=P10
1=VENDOR
2=OTHER
[ 0-2]
* When the coin vendor mode is selected:
1. Sort auto select is OFF.
2. For Japan, the duplex copy use inhibition setting is ON (inhibited).
3. When the auditor mode exclusive-setting is ON (manual paper feed inhibited) and the standard tray is set
to the manual feed tray, the standard tray setting is set to the main tray.
(Execution window)
OK/START Key
0 : No job separator
0
1 : Job separator provided
0
(When setting is changed, the machine does not shift to the code input window.)
Unit to be
Destination
used
SPF
EX Japan AB
series(FC)
Inch
series(FC)
Code: Setting
0 : Detection disabled
0
(Default for destinations other than below)
1 : FC detection enabled
(Default for SCA/Philippines)
0
Code: Mode
0 : Built-in auditor mode
0
1 : Coin vendor
2 : Other
0
AR-M207 M165 M162 SIMULATIONS 7-19
Contents
Sim25-10 LSU CHECK
EXEC
Document size
Set value
0(Disable)
FC(8.5"x13")
B4
B4
B4
FC(8.5"x13")
LG(8.5"x14")
LG(8.5"x14")
LG(8.5"x14")
Default:
00
1(Enable)
FC(8.5"x13")
FC(8.5"x13")
FC(8.5"x13")
FC(8.5"x13")
Default:
0 (P10)
Remark