7) Check that the following display is shown. Press the [Continue
Anyway] button.
8) When installation is completed, the following display is shown.
Press the [Finish] button.
The installation procedure (on Windows XP) is completed with the above
operation.
C. Installation procedure on Windows 2000
1) Machine side:
Executable by performing the Service Simulation No. 49-01 (Flash
Rom program-writing mode).
(A word "Download mode." appears on the operation panel to denote
the download mode status. )
2) Connect the machine and the PC with a USB cable.
(Be sure to connect the USB cable to the main unit side. Connection
to the optional dual function board cannot execute this function.)
3) Check that the new hardware search wizard is shown. Press the
[Next] button.
AR-M207 M165 M162 FLASH ROM VERSION UP PROCEDURE 12-2
4) Select "Search for a suitable driver for my device" and press the
[Next] button.
5) Select "Specify a location" and press the [Next] button.
6) If the reference position is not the folder which includes the
maintenance tool driver (Mainte.inf), select [Browse] button. If the
reference position is the folder which includes the maintenance tool
driver, press [OK] button to go to procedure (9).
7) Specify the folder which includes the maintenance tool driver
(Mainte.inf), and press [Open] button.