Shifter Operation Check; Job Separator Operation Check; Shifter Home Position Check - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
03
03

Shifter operation check

Used to reciprocate the shifter 4 times.
During execution, the status of the shifter HP sensor is displayed on the right upper section of the screen.
(When the sensor is detected, the display is highlighted.)
[CA] key: Exits the simulation mode.
[Interruption] key: Returns to the sub code input window.
* When the above end key is pressed during operation of the shifter, the shifter is returned to the home
position before terminating the operations.
(Initial window)
Sim3-3 SHIFTER CHK
PRESS OK KEY EXEC
04

Job separator operation check

Used to operate the job separator up and down for 30sec.
During operation, the status of the upper limit sensor and the lower limit sensor is displayed on the right
upper section of the display.
[CA] key: Exits the simulation mode.[Interruption] key: Returns to the sub code input window.
When the operation is interrupted, the job separator is shifted to the home position before terminating the
simulation similarly to the shifter.
(Initial window)
Sim3-4 JOBSEPA CHK
PRESS OK KEY EXEC
11

Shifter home position check

Used to check the operations of the shifter HP sensor and the shifter. When this simulation is executed, the
initial menu is displayed. By the following key operations, the left operation and the right operation of the
home position sensor and the shifter can be executed separately.
[
] key: Shifts to R side by the specified steps.
[
] key: Shifts to F side by the specified steps.
[ ] key: Shift to the home position.
[SFTHP] is highlighted when the HP sensor is detected.
(Initial window)
Sim3-11 SHIFTER CHK
SFTHP
[
]:R [
]:HP [
[CA] key: Exits the simulation mode.
[Interruption] key: Returns to the sub code input window.
Contents
(Execution window)
Sim3-3 SHIFTER CHK
OK/START Key
(Execution window)
Sim3-4 JOBSEPA CHK
OK/START Key
]:F
AR-M207 M165 M162 SIMULATIONS 7-6
SFTHP
EXEC
Display name
Sensor name
JSUP
JSUP
:Job separator upper limit sensor
JSDL
JSDL
:Job separator lower limit sensor
EXEC
Remark