Main
Sub
code
code
26
51

Copy temporary stop function setting

Used to set whether copying is stopped temporarily when the paper exit tray full is detected. When the
electronic sort function is used, paper exit of 250 sheets (*1) or more can be used for one copy job. If, at that
time, copying (paper discharge) is continued with the tray full, a paper exit jam may occur. To avoid this,
copying is temporarily stopped by this setting.
Sim26-51 COPY STOP
1:COPIES STOP
0=NON STOP
1=STOP
[ 0-1]
(*1) 150 sheets when the job separator is installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
54

LCD contrast PWM duty setting

Used to set the PWM duty (brightness) at the center value of LCD contrast.
* Setting range: 30-70(Default: 50)
* When [OK] key or [START] key is pressed, the set value of LCD contrast is immediately reflected.
Sim26-54 LCD DUTY
1:LCD PWM DUTY
[ 30- 70]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
60

FAX mode key Enable/Disable setting

Used to set Enable/Disable of the FAX mode key when the FAX PWB is not installed.
Though this setting is set to Enable, if the FAX PWB is not installed, a message of "FAX PWB is not
installed" is displayed.
* When the FAX PWB is installed, the display shifts to the FAX window regardless of this setting.
Sim26-60 FAX KEY
1:FAX KEY MODE
[
0-
Setting
(Enable)
(Disable)
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
73

Toner save setting display/non-display

Used to set Enable/Disable of the toner save setting in the key operator program. If this setting is set to
Enable (1), the toner save setting appears in the key operator program to allow setting.
Sim26-73 TS ENABLE
1:TS ENABLE
[
0- 1]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Display: Setting
0 : Temporary stop cancel
0
1 : Temporary stop (Default)
1
50
50
0
1]
0
Yes
FAX window display
FAX window display
Display: Setting
0 : Disable
0
1 : Enable
0
AR-M207 M165 M162 SIMULATIONS 7-24
Contents
FAX PWB
No
FAX not-installed display
Error beep sound
Remark
Default:
1 (Temporary stop)
Default:
50
Default:
0 (Enable)
Default:
01(Enable)