Ce Mark Conformity Control On/Off; Auditor Mode Exclusive Setup; Cancel Of Stop At Maintenance Life Over; Cancel Of Stop At Developer Life Over - Sharp AR-M207 Service Manual

Hide thumbs Also See for AR-M207:
Table of Contents

Advertisement

Main
Sub
code
code
26
30

CE mark conformity control ON/OFF

Used to set Yes/No of CE mark conformity.
When this simulation is executed, the current set value is displayed. Enter a value with 10-key and press
[OK] key or [START] key. The set value is saved to EEPROM and the machine returns to the sub code input
window.
Sim26-30 CE MARK
1:CE MARK CTRL
0=OFF
1=ON
[ 0-1]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
31

Auditor mode exclusive setup

Used to set whether paper feed is allowed from the manual paper feed tray of not when the auditor is set to
the coin vendor mode.
Sim26-31 AUDITOR
1:AUDITOR
[ 0-2]
* When this setting is set to ON, if the auditor mode is the coin vendor mode and the standard tray setting is
set to the manual paper feed tray, the standard tray setting is set to the main tray.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
36

Cancel of stop at maintenance life over

Used to set YES/NO of cancel of stop when the maintenance counter life is over.
Sim26-36 MAINTESTOP
1:MAINTE OVER
[ 0-1]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
37

Cancel of stop at developer life over

Used to set YES/NO of cancel of stop when the developer counter life is over.
Sim26-37 DEVE STOP
1:DEV LIFE OVER
[ 0-1]
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
39
Memory capacity check
Used to check the capacity of the image memory (SDRAM) installed to the MCU PWB and the capacity of
the IMC compression memory.
Sim26-39 MEMORY CHK
MCU
: 32Mbyte
IMC
: 16Mbyte
There are two kinds of the displayed image memory capacity: 16MB and 32MB.
The standard capacity of the IMC compression memory is 16B.
* It is not displayed when IMC is not installed.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
Contents
Code: Setting
0 : CE mark support control OFF (*Default of 100V series)
0
1 : CE mark support control ON (*Default of 200V)
0
Code: Setting
0 : Exclusive setting OFF (Manual paper feed enable)
1
1 : Exclusive setting ON (Manual paper feed disable) (Default)
2 : Exclusive setting OFF (Manual paper feed enable) + A3/WLT charge
1
Code: Setting
0 : Stop
1
1 : Stop cancel (Default)
1
Code: Setting
0 : Stop
1
1 : Stop cancel (Default)
1
AR-M207 M165 M162 SIMULATIONS 7-22
Remark
Default:
1 (ON)
Default:
1 (ON)
Default:
1 (Stop cancel)

Hide quick links: