Main
Sub
code
code
22
04
Jam total counter display
Used to display the jam total counter.
Sim22-4 COUNTER
JAM
:
07
Key operator code display
Used to display the key operator code.
Sim22-7 KEY OPE
KEY CODE:
09
Paper feed counter display
Used to display the paper feed quantity of each paper feed tray. This simulation shows the use frequency of
each paper feed section.
[CA] key: Exits the simulation mode.
[Interruption] key: Shifts to the sub code input window.
,
keys: Switches to another page.
Sim22-9 COUNTER 1/2
BYPASS
TRAY1
TRAY2
TRAY3
* TRAY2-TRAY4 are displayed only when they are installed.
13
CRUM destination display
Used to display the CRUM chip destination code saved in the EEPROM. If the display does not match the
destination code saved in the CRUM chip, it is judged as an error.
* This simulation is valid only for the model with the CRUM chip.
Sim22-13 CRUM
CRUM TYPE
14
P-ROM version display
Sim22-14 ROM VER1/2
S/N
MCU
IMC
PNL
The version of the option board which is not installed is not displayed.
nnnnnn
nnnnn
Key
: nnnnnnn
: nnnnnnn
: nnnnnnn
Key
: nnnnnnn
Number : Setting (Destination)
00
: Not set.
nn
01
: BTA-A
02
: BTA-B
03
: BTA-C
04
: BTA-E
12
: AL series
99
: Conversion
Sim22-14 ROM VER2/2
: -----------
FAX
: --.--
: --.--
: --.--
AR-M207 M165 M162 SIMULATIONS 7-15
Contents
Sim22-9 COUNTER 2/2
TRAY4
: nnnnnnn
S/N
:Production serial number
: --.--
MCU
:Main unit program version
IMC
:IMC program version
PNL
:Panel program version
FAX
:FAX program version
Remark