H4
00
Content
Heat roller low temperature detection.
Detail
When the fusing temperature is lower than
150C° after 55sec from the start of warming
up.
When the warming up complete temperature is
not reached in 30sec from reaching 150C°.
When the fusing temperature is lower than
100C° after 20sec from ready start.
When the fusing temperature is lower than
145C° when printing.
Cause
Thermistor abnormality.
Heater lamp abnormality.
Thermostat abnormality.
Control PWB abnormality.
Check
Use SIM 5-02 to check the heater lamp blinking
and
operation.
remedy
When the lamp blinks normally.
Check the thermistor and its harness.
Check the thermistor input circuit on the control
PWB.
When the lamp does not light up.
Check for disconnection of the heater lamp and
the thermostat. Check the interlock switch.
Check the power PWB and the lamp control
circuit on the MCU PWB.
Use SIM 14 to clear the self diagnostic display.
H5
01
Content
5-time continuous detections of POUT not-
reached jam.
Detail
Paper not-reached jams are detected 5 times
or more continuously by the paper exit sensor
(POUT). The jam counter is backed up and
used for jobs after turning on the power.
Cause
A fusing jam is not canceled completely. (A jam
paper remains in the machine.)
Paper exit sensor trouble or harness
connection trouble
Defective installation of the fusing unit.
Check
Check the fusing section jam (for winding, etc.).
and
Check the POUT sensor harness. Check
remedy
installation of the fusing unit.
Use SIM14 to clear the self diag display.
L1
00
Content
Scanner feed trouble.
Detail
The scanner does not complete feeding in the
specified time.
Cause
Mirror unit abnormality.
The scanner wire is disconnected.
The origin detection sensor abnormality.
Mirror motor harness abnormality.
Check
Use SIM 1-1 to check the mirror reciprocating
and
operations.
remedy
When the mirror does not feed.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor.
Details of trouble
AR-M207 M165 M162 TROUBLE CODE LIST 8-4
Main
Sub
code
code
L3
00
Content
Scanner return trouble.
Detail
The scanner does not complete returning in
the specified time.
The mirror is not in the home position when OC
copying is started with the mirror standby in the
home position.
Cause
Mirror unit abnormality.
Scanner wire disconnection.
Origin detection sensor abnormality.
Mirror motor harness abnormality.
Check
Use SIM 1-1 to check the mirror reciprocating
and
operations.
remedy
When the mirror does not return.
Check for disconnection of the scanner wire.
Check the harness and the connector between
the mirror motor and the MCU PWB.
Replace the mirror unit.
Replace the MCU PWB.
When the mirror does feed.
Use SIM 1-2 to check the mirror home position
sensor.
L4
01
Content
Main motor lock detection.
Detail
The main motor does not rotate.
The motor lock signal is detected for 1sec or
more after rotation of the main motor.
The motor lock signal is detected for 1sec
during rotation of the main motor.
Cause
Main motor unit abnormality.
Improper connection or disconnection the main
motor and the harness.
MCU PWB abnormality.
Check
Use SIM 25-01 to check the main motor
and
operations.
remedy
Check connection of the main motor harness/
connector.
Replace the main motor.
Replace the MCU PWB.
11
Content
Shifter motor trouble.
Detail
The shifter home position detection signal is
not detected when initializing the shifter.
Cause
Shifter motor abnormality, improper connection
or disconnection of the harness, shifter home
position sensor abnormality.
Check
Use SIM 03-11 to check the shifter motor
and
operations.
remedy
Check connection of the harness/connector of
the shifter motor.
Replace the shifter motor.
Replace the MCU PWB.
L6
10
Content
Polygon motor lock detection.
Detail
The polygon motor does not rotate.
The motor lock signal is detected for 6sec after
rotation of the polygon motor. The motor lock
signal is detected for 1sec during rotation of the
polygon motor.
Cause
Polygon motor unit abnormality.
Improper connection or disconnection of the
polygon motor and the harness.
MCU PWB abnormality.
Check
Use SIM 61-1 to check the polygon motor
and
operations.
remedy
Check connection of the polygon motor
harness/connector.
Replace the polygon motor.
Replace the MCU PWB.