Gradual Cooling - GIRBAU HS-6013 Operation Instructions Manual

Table of Contents

Advertisement

7.3.10. Gradual cooling.

Function that allows gradually reducing the bath temperature by admitting cold water up to 45ºC / 113ºF.
The cooling is executed once the rotation time ends and before the bath is drained.
This function is only programmable if the temperature programmed in the phase is greater than 50ºC / 122ºF.
Possible programming:
No gradual cooling.
< < < Option programmed by default
Yes, gradual cooling
7.3.11. Cooling gradient
This function only appears if the COOLING GRADIENT parameter has been activated in the
CONFIGURATION menu and if gradual cooling YES has been programmed in the previous stage.
Controlling the cooling of the bath is possible in different gradients defined in degrees/minute.
The water temperature can modify the cooling speed, mainly in the fastest gradients.
Cooling gradients
Value in Centigrade degrees: 1º / minute
Value in Fahrenheit degrees: 2º / minute
Value in Centigrade degrees: 3º / minute
Value in Fahrenheit degrees: 5,5º / minute
< < < Option programmed by default
Value in Centigrade degrees: 5º / minute
Value in Fahrenheit degrees: 9º / minute
Value in Centigrade degrees: 10º / minute
Value in Fahrenheit degrees: 18º / minute
7.3.12. Draining
This function opens the drain valve.
The drum rotation speed during draining and the drain time are programmed in successive operations.
Possible programming:
No draining in the phase.
Yes, draining in the phase.
< < < Option programmed by default
Programming mode
Optional programming
27
Cod. 429159
Rev. 01/0306

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eh030Hs-6017Eh040

Table of Contents