7.3.15. Buzzer.

This buzzer is programmable at the end of each phase.
By default, the buzzer lasts 2 seconds. This value can be modified in the corresponding section of the
CONFIGURATION menu.
BUZZER and PAUSE programming
This function appears only if PROGRAMMABLE PAUSE in the CONFIGURATION menu is activated.
The programming of this parameter:
stops the wash program from advancing to the end of the phase.
activates the buzzer for the seconds selected while configuring the parameters.
keeps rotation programmed in the phase.
does not allow door opening.
To resume the wash programme, press the
Possible programming:
No buzzer
< < < Option programmed by default
Yes, buzzer
Programme pause and buzzer during the specified time in CONFIGURATION menu.
7.3.16. End of phase or program
When the last operation of the phase has been programmed, a screen with two options appear:
Access to programming a new phase.
The acceptance of this option creates a new one.
The number of the phase appears in the upper, central box on the screen and the first operation of
the new phase appears in the central box.
End of program. The previous menu is directly accessed.
The microprocessor is ready again to receive new programming or modification orders.
By pressing the key ---↵--- several times, the top menus are accessed.
Programming mode
Optional programming
CONT
key on the multifunction keyboard.