Resetting All Jobs; General Operating Problems; Interface For Automated Welding - EWM Phoenix 401 Progress puls MM FKW Operating Instructions Manual

Table of Contents

Advertisement

Rectifying faults

General operating problems

7.3.2

Resetting all JOBs

JOBs 1–128 and 170–256 will be reset.
Custom JOBs 129–169 are maintained.
Display
7.4
General operating problems
7.4.1

Interface for automated welding

No function of the external interrupt equipment (emergency stop switch)!
If the emergency stop circuit has been realised using an external interrupt equipment
via the interface for automated welding, the machine must be configured for this setup.
If this is not observed, the power source will ignore the external interrupt equipment
and will not shut down!
Disconnect jumper 1 on PCB T320/1 (Tetrix / forceTig) or M320/1 (Phoenix / alpha Q)!
114
ENTER
3 s
JOB-
LIST
Setting/selection
Reset to factory settings
The RESET will be done after pressing the button.
The menu will be ended when no changes are done after 3 sec.
NOTE
RESET
3 s
Figure 7-2
WARNING
JOB-
LIST
EXIT
3 s
099-005323-EW501
21.05.2014