5.8.11.2 MIG/MAG overview of parameters

P
START
of the wire feed value of the main program P
absolute manner, if desired (see Setting of special parameter P21).
Basic Parameters
Item
Meaning / Explanation
1
1 Gas pre-flow time
2
2 P
START
Wire speed, relative
Arc length correction
3
3 Duration
4
4 Slope duration from P
5
5 P
A
Wire speed, absolute
6
7 Duration (spot time and superpulse)
7
8 P
B
Wire speed, relative
Arc length correction, relative
8
9 Duration
9
Slope duration from P
1
0
10 1
P
END
1
Wire speed, relative
Arc length correction
11 1
Duration (superpulse)
2
12 1
Gas post-flow time
3
13 1
Superpulses
4
66
, P
, and P
are set as relative programs ex faxtory. They relate to percentages
B
END
to P
START
A
to P
A
END
NOTE
. These programs can also be set in an
A
Figure 5-30
Setting Range
0.0s to 20.0s
1% to 200%
-9.9V to +9.9V
0.0s to 20.0s
0.0s to 20.0s
0.1 m/min to 40 m/min
0.01s to 20.0s
1% to 200%
-9.9V to +9.9V
0.01s to 20.0s
0.0s to 20s
1% to 200%
-9.9V to +9.9V
0.0s to 20s
0.0s to 20s
On / Off