Design and function
MIG/MAG welding

5.8.11.5 Example, aluminium welding (latched special)

Basic parameters
Welding parameter
GASstr
GASend:
RUECK
"P
" start program
START
Welding parameter
DVstart
ustart
tstart
"P
" main program
A
Welding parameter
"P
" reduced main program
B
Welding parameter
DV3
U3
"P
" end-crater program
END
Welding parameter
tSend
DVend
Uend
tend
68
Figure 5-33
Meaning / explanation
Gas pre-flow time
Gas post-flow time
Wire burn-back length
Meaning / explanation
Wire speed
Arc length correction
Duration
Meaning / explanation
Setting the wire speed
Meaning / explanation
Wire speed
Arc length correction
Meaning / explanation
Slope duration from P
or P
A
Wire speed
Arc length correction
Duration
to P
B
END
Setting range
0.0s to 20.0s
0.0s to 20.0s
2 to 500
Setting range
0% to 200%
-9.9V to +9.9V
0.0s to 20s
Setting range
Setting range
0% to 200%
-9.9V to +9.9V
Setting range
0.0s to 20s
0% to 200%
-9.9V to +9.9V
0.0s to 20s