8.2

Phoenix 501 Progress FKW

Setting range for welding current
Setting range for welding voltage
Duty cycle
60%
65%
100%
Load alternation
Open circuit voltage
Mains voltage (tolerances)
Frequency
Mains fuse (safety fuse, slow-blow)
Mains connection lead
Maximum connected load
Max. connected load
Recommended generator rating
Cos
Insulation class/protection
classification
Ambient temperature*
Machine/torch cooling
Cooling capacity at 1 l/min
Max. flow rate
Max. coolant outlet pressure
Max. tank capacity
Coolant
Workpiece lead
Dimensions L x W x H in mm
Weight
Wire feed speed
Standard roller installation
Drive type
Welding torch connection
EMC class
Constructed to standards
Ambient temperature depends on coolant!
*
Observe the coolant temperature range for the welding torch cooling!
099-005323-EW501
21.05.2014
TIG
10.2 V–30.0 V
14.3 V–39.0 V
40 °C
25 °C
40 °C
500 A
-
500 A
-
500 A
-
430 A
460 A
430 A
10 min. (60% DC
3 x 400 V (-25% to +20%)
H07RN-F4G6
19.3 kVA
-25 °C to +40 °C
Fan/gas or water
Ex works: KF 23E (-10 °C to +40 °C) or
KF 37E (-20 °C to +10 °C)
1100 x 455 x 950
0.5 m/min. to 24 m/min.
1.0 mm + 1.2 mm (for steel wire)
4-roller (37 mm)
Euro torch connector
IEC 60974-1, -2, -5, -10
NOTE
Technical data
Phoenix 501 Progress FKW
MIG/MAG
MMA
5 A–500 A
20.2 V–40.0 V
25 °C
40 °C
-
500 A
500 A
-
460 A
430 A
6 min. welding, 4 min. pause)
79 V
50/60 Hz
3 x 32 A
24.9 kVA
25.6 kVA
34,6 kVA
0.99
H/IP 23
1500 W
5 l/min
3.5 bar
12 l
95 mm²
124 kg
A
/
25 °C
-
500 A
460 A