EWM Phoenix 401 Progress puls MM FKW Operating Instructions Manual page 81

Table of Contents

Advertisement

Latched mode
Selection
Select latched operating mode
Step 1
Press and hold torch trigger
Shielding gas is expelled (gas pre-flows)
The arc is ignited using liftarc.
Welding current flows with pre-selected setting.
Step 2
Release torch trigger (no effect)
Step 3
Press torch trigger (no effect)
Step 4
Release torch trigger
Arc is extinguished.
Gas post-flow time elapses.
099-005323-EW501
21.05.2014
Figure 5-44
.
Design and function
TIG welding
81