Checking the Operating Status of
the VTR Module
You can check the operating status of the VTR
module in the subdisplay. When the unit is in
recording pause mode, you can also use this page
to switch the power supply to the VTR module
between power saving (SAVE) mode and standby
(STBY) mode.
The first line shows the operating status of the
VTR module (REC PAUSE, REC, F.FWD,
REW, PLAY, STOP, etc).
The second line shows the VTR module power
supply mode (SAVE, STBY) when it is in stop
mode (STOP), recording pause mode (REC
PAUSE), or playback pause mode (PLAY
PAUSE). Use an assignable button/switch to
which the VTR SAVE function is assigned to
select SAVE or STBY.
For details, see "Assigning Functions to Assignable
Buttons/Switch" (page 54).
Checking Timecode and the
Remaining Tape Time
The timecode/tape remaining page allows you to
check timecode and the approximate remaining
tape time (unit: minutes).
Timecode/tape remaining page
The first line displays a timecode value, and the
second line displays the approximate tape
remaining time, within the range 1 to 99 minutes.
The following table lists the types of timecode
that appear.
Indication
TCR 00:00:00:00
TCR 00:00.00:00
52
Basic Settings with the Subdisplay
Meaning
Timecode data of the LTC
reader
Timecode data of the LTC
reader (DF)
Indication
Meaning
TCR.00:00:00:00
Timecode data of the VITC
reader
UBR 00 00 00 00
User bit data of the LTC
reader
UBR.00 00 00 00
User bit data of the VITC
reader
TCG 00:00:00:00
Timecode data of the
timecode generator
TCG 00:00:00.00
Timecode data of the
timecode generator (DF)
UBG 00 00 00 00
User bit data of the timecode
generator
CTL -0:00:00:00
Data of the CTL counter
T*R 00:00:00:00
Timecode cannot be read with
the LTC reader.
U*R 00 00 00 00
User bits cannot be read with
the LTC reader.
T*R.00:00:00:00
Timecode cannot be read with
the VITC reader.
U*R.00 00 00 00 User bits cannot be read
with the VITC reader.
See "To select time data to display during playback"
(page 94) for information about how to switch
between different types of timecode.
Setting the Timecode Generator
Value to XX:00:00:00
You can set the current timecode generator value
to the "00:00:00" value of the next hour.
Example: TCG 01:12:34:12 t TCG 02:00:00:00
You can perform this setting from the control
panel or the subdisplay/menu operations section.
To perform the setting from the control panel
Press the TC button while holding the FUNC and
BACK buttons down.
To perform the setting from the subdisplay/menu
operations section
When the TCG is displayed in the subdisplay,
press the SET button while holding the MENU
SEL/ENTER dial down.