Hmc Surveillance Error Codes - IBM P 615 series Service Manual

Table of Contents

Advertisement

HMC Surveillance Error Codes

The HMC surveillance error codes generated only by the HMC are listed in the following table.
Error Code
B301 0001 HMC/partition surveillance fault
B301 0002 HMC/partition surveillance fault
B301 0012 HMC/partition surveillance fault
B301 0013 HMC/partition surveillance fault
B301 0019 HMC/partition surveillance fault
B301 0020 HMC/partition surveillance fault
B301 0023 HMC/partition surveillance fault
B301 0025 HMC/partition surveillance fault
B301 0026 HMC/partition surveillance fault
B301 0027 HMC/partition surveillance fault
B301 0029 HMC/partition surveillance fault
B301 002B HMC/partition surveillance fault
B301 002C HMC/partition surveillance fault
B301 002D HMC/partition surveillance fault
B302 0001 HMC/partition surveillance fault
214
EserverpSeries 615 Service Guide
Description
Action/ Possible Failing FRU
Contact service support.
Verify the network between the HMC and the
partition by pinging in both directions. If
problems are found, correct them. Reboot the
HMC.
Contact service support.
Contact service support.
Contact service support.
Contact service support.
Contact service support.
Contact service support.
Contact service support.
1. If short host names are being used for the
HMC and the partitions, ensure that the
short host names are set up correctly
according to the instructions in "Using
Network Adapters to Communicate with
Partitions" in the IBM Hardware
Management Console for pSeries
Installation and Operations Guide. Correct
any problems that are found, then verify
that you can ping in both directions between
the HMC and partitions.
2. If short host names are not being used, or
the previous step does not correct the
problem, contact service support.
Contact service support.
Contact service support.
Contact service support.
Contact service support.
1. If short host names are being used for the
HMC and the partitions, ensure that the
short host names are set up correctly
according to the instructions in "Using
Network Adapters to Communicate with
Partitions" in the IBM Hardware
Management Console for pSeries
Installation and Operations Guide. Correct
any problems that are found, then verify
that you can ping in both directions between
the HMC and partitions.
2. If short host names are not being used, or
the previous step does not correct the
problem, contact service support.