Post Error Codes - IBM x3250 M2 Problem Determination And Service Manual

Hide thumbs Also See for x3250 M2:
Table of Contents

Advertisement

Clearing the error logs
For complete information about using the Configuration/Setup Utility program, see
the User's Guide.
To clear the error logs, complete the following steps:
1. Turn on the server.
2. When the prompt Press F1 for Configuration/Setup is displayed, press F1. If
3. Use one of the following procedures:

POST error codes

The following table describes the POST error codes and suggested actions to
correct the detected problems.
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 3, "Parts listing, Types 4190, 4191 and 4194 server," on page 31 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units
(FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Error code
Description
062
Three consecutive boot failures using the
default configuration.
101, 102
System board failure.
you have set both a power-on password and an administrator password, you
must type the administrator password to view the error logs.
v To clear the BMC system-event log, select Advanced Setup, select
Basement Management Controller (BMC) Settings, and then select BMC
System Event Log. Use the Down Arrow key to select Clear BMC SELs;
then, press Enter. Press Enter to confirm clearing the log, and then press
Esc.
v To clear the system event/error log, select Event/Error logs, and then select
System Event/Error Log. Use the Down Arrow key to select Clear System
Event/Error Log; then, press Enter. Press Enter to confirm clearing the log,
and then press Esc.
v To clear the RSA II event/error log, select Event/Error logs, and then select
RSA II Event/Error Log. Use the Down Arrow key to select Clear RSA II
logs; then, press Enter. Press Enter to confirm clearing the log, and then
press Esc.
Action
1. Update the system firmware to the latest level
(see "Updating the firmware" on page 13).
2. (Trained service technician only) Replace the
system board.
(Trained service technician only) Replace the system
board
103
Chapter 5. Diagnostics

Advertisement

Table of Contents
loading

Table of Contents