5. Select [1 Yes]. The message
shown in the right figure appears.
6. Press the
off. When you turn the power on
next time, the operating time for a
replacement part is reset to 0.
7.8.2

Correction for the replaced rate gyro

Note: Set this menu only when replacing a rate gyro. Be sure to connect each plug to
the correct socket (see "Antenna Unit GS-1001" on page AP-22). Do not change the
setting unless a rate gyro is replaced. Enter the correct value. Otherwise performance
may be affected.
1. Press the MENU ESC key to open the main menu.
2. Select [4 Maintenance] then [5 Exchange].
3. Select [2 Sensor Unit].
4. Select [2 Rate Gyro (x)], [3 Rate Gyro (y)] or
[4 Rate Gyro (z)].
5. Enter the correction value with the numeric keys as follows. The correction value
is indicated on the seal attached to the rate gyro.
To switch between + and -, press the cursorpad (◄) to move the cursor here
then press any numeric key.
6. Move the cursor to [Enter] then press the ENT key. The message "Processing..."
appears. If normal, the last-used screen appears. If abnormal, the message "Re-
sponse Error!!!" appears. If timeout occurred, the message "Time Out!!!" appears.
key to turn the power
1) For example, to enter "+1.5", press the
2) Press the 1 key. The cursor moves here
3) Press the 5 key.
7. MAINTENANCE, TROUBLESHOOTING
cursorpad (►) to move the cursor here.
and "+" appears.
7-9