Auto Switch panel
Auto switch mode automatically switches inputs based on detected input signals.
Figure 59.
Auto Switch Panel
1.
Select the
Enable Auto Switch
2.
Click the radio button of the desired type of auto switch mode from the following:
Priority to the highest active input number
the input to the highest numbered active input.
Priority to the lowest active input number
input to the lowest numbered active input.
HDCP Mode panel
When enabled, the HDCP mode can be set to either follow the current input, with or without
DVI trials, or always encrypt the output, with or without DVI trials.
Figure 60.
HDCP Mode Panel
Select one of the following radio buttons:
— Encrypts the output only when required by the selected input source.
Follow Input
Always Encrypt Output
status of the selected input source.
Follow Input (with continuous DVI trials)
required by the selected input source. Use this setting when DVI sink devices initially
pass HDCP encrypted content, but intermittently display a green HDCP notification
screen after a power cycle or resuming from sleep mode.
Always Encrypt Output (with continuous DVI trials)
the output regardless of the HDCP status of the selected input source. Use this setting
when DVI sink devices initially pass HDCP encrypted content, but intermittently display
a green HDCP notification screen after a power cycle or resuming from sleep mode.
IN1604 DTP and IN1604 HD Scalers • Configuration Software
check box to enable auto switch mode.
— Always encrypts the output, regardless of the HDCP
— Encrypts the output only when
— Automatically switches
— Automatically switches the
— Always encrypts
76