Siemens HiPath BizIP AD 20 Administration Manual page 63

Hipath bizip access device/ telephones
Table of Contents

Advertisement

2. The following configuration depends on the option selected:
With Predefined Service:
– Select the service category from the Service Category list, e.g.
Servers.
– Select the required service from the Predefined Service list, e.g.
FTP Server.
– You can limit the permitted IP address space for requests from the
Internet under Source IP Address. All means no limit; when you se-
lect Single enter the only permitted IP address under IP Address.
Alternatively, you can select Subnet, to limit yourself to a particular
subnetwork.
Under Manually defined:
– Enter the service name under Service Name.
– You can limit the permitted IP address space for requests from the
Internet under Source IP Address. All means no limit; when you se-
lect Single enter the only permitted IP address under IP Address.
Alternatively, you can select Subnet, to limit yourself to a particular
subnetwork.
– Select the protocol used for this service from the Protocol list
– Enter the port area of the external connection partner as the port lim-
its in the fields for External Port.
– Enter the port in your own LAN in the Internal Port field.
3. Enter the IP address in your own LAN that provides the service in the
fields under Destination IP Address.
4. Click Add to add the entry to the list. You can remove each entry from
the list by clicking Delete.
5. Click Apply to apply your changes.
Security for your HiPath BizIP
63

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath bizip 410

Table of Contents