v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3250 M3 Types 4251, 4252, and 4261," on page 119 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
Fault in slot System board on
system %1.
(%1 = CIM_ComputerSystem.
ElementName)
Redundancy Bckup Mem Status has
been reduced.
IMM Network Initialization Complete. Info
Certificate Authority %1 has
detected a %2 Certificate Error.
(%1 = IBM_CertificateAuthority.
CADistinguishedName;
%2 = CIM_PublicKeyCertificate.
ElementName)
Ethernet Data Rate modified from
%1 to %2 by user %3.
(%1 = CIM_EthernetPort.Speed;
%2 = CIM_EthernetPort.Speed;
%3 = user ID)
48
IBM System x3250 M3 Types 4251, 4252, and 4261: Problem Determination and Service Guide
Error
Error
Redundancy has been lost
and is insufficient to continue
operation.
An IMM network has
completed initialization.
Error
A problem has occurred with
the SSL Server, SSL Client,
or SSL Trusted CA certificate
that has been imported into
the IMM. The imported
certificate must contain a
public key that corresponds
to the key pair that was
previously generated by the
Generate a New Key and
Certificate Signing Request
link.
Info
A user has modified the
Ethernet port data rate.
a. Check the extender-card
LEDs.
b. Reseat the affected adapters
and extender card.
c. Update the server and adapter
firmware (UEFI and IMM).
Important: Some cluster
solutions require specific code
levels or coordinated code
updates. If the device is part
of a cluster solution, verify that
the latest level of code is
supported for the cluster
solution before you update the
code.
d. Remove both adapters.
e. Replace the PCIe adapter.
f. Replace the extender card.
g. (Trained service technician
only) Replace the system
board.
a. Check the system-event log
for DIMM failure events
(uncorrectable or PFA) and
correct the failures.
b. Re-enable mirroring in the
Setup utility.
No action; information only.
a. Make sure that the certificate
that you are importing is
correct.
b. Try importing the certificate
again.
No action; information only.