Table 6. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3250 M3 Types 4251, 4252, and 4261," on page 119 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
215-802-xxx
Optical Drive
215-803-xxx
Optical Drive
106
IBM System x3250 M3 Types 4251, 4252, and 4261: Problem Determination and Service Guide
Test
State
Description
Aborted
The media tray
v Verify
is open.
Media
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Failed
The disc might
v Verify
be in use by
Media
the system.
Installed
v Read/
Write Test
v Self-Test
Messages
and actions
apply to all
three tests.
Action
1. Close the media tray and wait 15 seconds.
2. Run the test again.
3. Insert a new CD/DVD into the drive and wait
for 15 seconds for the media to be recognized.
4. Run the test again.
5. Check the drive cabling at both ends for loose
or broken connections or damage to the cable.
Replace the cable if it is damaged.
6. Run the test again.
7. Make sure that the DSA code is at the latest
level. For the latest level of DSA code, go to
http://www.ibm.com/support/
docview.wss?uid=psg1SERV-DSA.
8. Run the test again.
9. For additional troubleshooting information, go to
http://www.ibm.com/support/
docview.wss?uid=psg1MIGR-41559.
10. Run the test again.
11. Replace the CD/DVD drive.
12. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Wait for the system activity to stop.
2. Run the test again
3. Turn off and restart the system.
4. Run the test again.
5. Replace the CD/DVD drive.
6. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.