IBM x3250 M3 Problem Determination And Service Manual page 118

Hide thumbs Also See for x3250 M3:
Table of Contents

Advertisement

Table 6. DSA Preboot messages (continued)
v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved.
v See Chapter 4, "Parts listing, System x3250 M3 Types 4251, 4252, and 4261," on page 119 to determine which
components are customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a Trained
service technician.
v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information, hints, tips,
and new device drivers or to submit a request for information.
Message
number
Component
201-805-xxx
Memory
201-806-xxx
Memory
201-807-xxx
Memory
100
IBM System x3250 M3 Types 4251, 4252, and 4261: Problem Determination and Service Guide
Test
State
Description
Memory Test
Aborted
Test canceled:
the memory
controller
display/alter
write operation
was not
completed.
Memory Test
Aborted
Test canceled:
the memory
controller fast
scrub operation
was not
completed.
Memory Test
Aborted
Test canceled:
the memory
controller buffer
free request
failed.
Action
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 193.
4. Run the test again.
5. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 193.
4. Run the test again.
5. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.
1. Turn off and restart the system.
2. Run the test again.
3. Make sure that the server firmware is at the
latest level. The installed firmware level is shown
in the DSA event log in the Firmware/VPD
section for this component. For more
information, see "Updating the firmware" on
page 193.
4. Run the test again.
5. If the failure remains, go to the IBM website for
more troubleshooting information at
http://www.ibm.com/systems/support/
supportsite.wss/docdisplay?brandind=5000008
&lndocid=SERV-CALL.