IBM x3250 M3 Problem Determination And Service Manual page 48

Hide thumbs Also See for x3250 M3:
Table of Contents

Advertisement

v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See Chapter 4, "Parts listing, System x3250 M3 Types 4251, 4252, and 4261," on page 119 to determine
which components are customer replaceable units (CRU) and which components are field replaceable
units (FRU).
v If an action step is preceded by "(Trained service technician only)," that step must be performed only by a
trained service technician.
v Go to the IBM support website at http://www.ibm.com/systems/support/ to check for technical information,
hints, tips, and new device drivers or to submit a request for information.
Error code
Description
3048006
Booted secondary (backup) UEFI image
because of ABR
305000A
RTC date/time is incorrect
3058001
System configuration invalid
3058004
Three boot failure
3108007
System configuration restored to default
settings
30
IBM System x3250 M3 Types 4251, 4252, and 4261: Problem Determination and Service Guide
Action
1. Run the Setup utility, select Load Default
Settings, and save the settings to recover the
primary UEFI settings.
2. Turn off the server and remove it from the power
source.
3. Reconnect the server to the power source, then
turn on the server.
1. Adjust the date and time settings in the Setup
utility, and then restart the server.
2. Reseat the battery.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. (Trained service technician only) System
board
1. Run the Setup utility, and select Save Settings.
2. Run the Setup utility, select Load Default
Settings, and save the settings.
3. Replace the following components one at a time,
in the order shown, restarting the server each
time:
a. Battery
b. Failing device (if the device is a FRU, it must
be replaced by a trained service technician
only)
c. (Trained service technician only) System board
1. Undo any recent system changes, such as new
settings or newly installed devices.
2. Make sure that the server is attached to a reliable
power source.
3. Remove all hardware that is not listed on the
ServerProven website at http://www.ibm.com/
servers/eserver/serverproven/compat/us/.
4. Make sure that the operating system is not
corrupted.
5. Run the Setup utility, save the configuration, and
then restart the server.
6. See "Problem determination tips" on page 117.
Information only. This message is usually associated
with the CMOS battery clear event.