Sfp Lnk Leds Do Not Turn On; 100/1000 Leds Do Not Turn On; 100/1000 Ethernet Port Data Transmission; Table 83 Sfp Lnk Led Troubleshooting - ZyXEL Communications IES-1248-51 User Manual

Adsl+ ip dslam
Hide thumbs Also See for IES-1248-51:
Table of Contents

Advertisement

IES-1248-51 User's Guide

51.3 SFP LNK LEDs Do Not Turn On

The LEDs for one of the SFP slots do not turn on.

Table 83 SFP LNK LED Troubleshooting

STEPS
1
2
3
4

51.4 100/1000 LEDs Do Not Turn On

A 100/1000 Ethernet port's LEDs do not turn on.

Table 84 100/1000 LED Troubleshooting

STEPS
1
2
3
4

51.5 100/1000 Ethernet Port Data Transmission

The Ethernet port's LED is on, but data cannot be transmitted.

Table 85 Troubleshooting Data Transmission

STEPS
1
2
3
360
CORRECTIVE ACTION
Make sure that the Ethernet port's mode is set to match that of the peer Ethernet device.
Check the cable and connections between the SFP slot and the peer Ethernet device.
Check the mini GBIC transceiver.
Make sure that the peer Ethernet device is functioning properly.
If the cable, transceiver and peer Ethernet device are all OK and the LEDs stay off, there
may be a problem with the SFP slot. Contact the distributor.
CORRECTIVE ACTION
Each 100/1000M RJ-45 Ethernet port is paired with a mini GBIC slot. The IES-1248-51
uses one connection per pair.
Check the Speed Mode settings in the ENET Port Setup screen. Make sure that the 100/
1000 Ethernet port's connection speed is set to match that of the port on the peer
Ethernet device. When an Ethernet port is set to Auto, the IES-1248-51 tries to make a
fiber connection first and does not attempt to use the RJ-45 port if the fiber connection is
successful.
Check the Ethernet cable and connections between the 100/1000 Ethernet port and the
peer Ethernet device.
Use 1000Base-T 4-pair (8 wire) UTP Cat. 5 Ethernet cables with the RJ-45 interface.
Make sure that the peer Ethernet device is functioning properly.
If the Ethernet cable and peer Ethernet device are both OK and the LEDs still stay off,
there may be a problem with the port. Contact the distributor.
CORRECTIVE ACTION
Make sure that the Ethernet port has the appropriate mode setting.
Make sure that the IES-1248-51's IP settings are properly configured.
Check the VLAN configuration.
Chapter 51 Troubleshooting