IES-1248-51 User's Guide
Table 53 SNMPv2 Traps (continued)
TRAP NAME
overheatOver
fanRpmLow
fanRpmNormal
voltageOutOfRange
voltageNormal
extAlarmInputTrigger
extAlarmInputRelease
thermalSensorFailure
adslAtucLof
adslAturLof
adslAtucLos
adslAturLos
adslAturLpr
adslAtucLofClear
adslAturLofClear
adslAtucLosClear
adslAturLosClear
adslAturLprClear
adslAtucPerfLofsThreshTrap
adslAtucPerfLossThreshTrap
adslAtucPerfLprsThreshTrap
adslAtucPerfESsThreshTrap
adslAtucPerfLolsThreshTrap
adslAturPerfLofsThreshTrap
196
DESCRIPTION
This trap is sent when the system is no longer overheated. The variable
is the current system temperature in Celsius.
This trap is sent when the RPM of the fan is too low. The variable is the
current RPM of the fan.
This trap is sent when the RPM of the fan is back within the normal
range. The variable is the current RPM of the fan.
This trap is sent when the voltage of the system is out of the normal
range. The variable is the current voltage of the system in volts.
This trap is sent when the voltage of the system is back within the
normal range. The variable is the current voltage of the system in volts.
This trap is sent when there is an external alarm input.
This trap is sent when the external alarm input stops.
This trap is sent when the thermal sensor fails.
This trap is sent when a Loss Of Frame is detected on the ATUC.
This trap is sent when a Loss Of Frame is detected on the ATUR.
This trap is sent when a Loss Of Signal is detected on the ATUC.
This trap is sent when a Loss Of Signal is detected on the ATUR.
This trap is sent when a Loss Of Power is detected on the ATUR.
This trap is sent when the Loss Of Frame detected on the ATUC is
over.
This trap is sent when the Loss Of Frame detected on the ATUR is
over.
This trap is sent when the Loss Of Signal detected on the ATUC is
over.
This trap is sent when the Loss Of Signal detected on the ATUR is
over.
This trap is sent when the Loss Of Power detected on the ATUR is
over.
The number of times a Loss Of Frame has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Frame has occurred within the 15-minute interval.
The number of times a Loss Of Signal has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Signal has occurred within the 15 minute interval.
The number of times a Loss Of Power has occurred within 15 minutes
for the ATUC has reached the threshold. currValue is the number of
times a Loss Of Power has occurred within the 15-minute interval.
The number of error seconds within 15 minutes for the ATUC has
reached the threshold. currValue is the number of error seconds that
have occurred within the 15-minute interval.
The number of times a Loss Of Link has occurred within 15 minutes for
the ATUC has reached the threshold. currValue is the number of times
a Loss Of Link has occurred within the 15-minute interval.
The number of times a Loss Of Frame has occurred within 15 minutes
for the ATUR has reached the threshold. currValue is the number of
times a Loss Of Frame has occurred within the 15-minute interval.
Chapter 31 Access Control