Important Note:
to escape from programming no matter how much has been completed, then begin again at step 1.

3.1.2 Single or Multiple Systems

This program sequence sets the telephone entry system to operate as a single unit on the phone line, or to share the phone line
with other units. If multiple systems are sharing the same phone line, then each one must be set as a "multiple system" and
each must have a unique master code.
Factory setting = 0 (Single System)
OPER
OPER
GHI
GHI
1. Press
0 0
4 4
OPER
OPER
2. Press
(beep) for a single system, OR
0 0
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0

3.1.3 Relay Strike Time

These steps will program Relay 1 and Relay 2 strike times. Strike times can be programmed from 1/4 second (enter 00 in step
3) up to 99 seconds by entering the desired time in seconds.
Factory setting for relay strike times are: Relay 1 = 01 (1 sec), Relay 2 = 01 (1 sec).
OPER
OPER
DEF
DEF
1. Press
0 0
3 3
SP
SP
2. Press
(beep) to set Relay 1, OR
1 1
3. Enter the two-digit strike time in seconds (00-99), then press
(Example: 1/4 second - enter 00, 1 second - enter 01 etc.)
4. Repeat steps 2 and 3 to set other relay strike time.
OPER
OPER
5. Press
together to end this programming sequence (beeeeeep).
0 0

3.1.4 "Tone Open" Sound ON or OFF

The following programming sequence turns the "Tone Open" sound either On or Off (when the relays activate). This feature is
available on Rev L boards or higher. See 3.1.6 for information about "Tone Open" numbers feature.
Factory setting = 1 (tone ON)
SP
SP
PQRS
PQRS
1. Press
1 1
7 7
The LCD display will read: 1=Y 0=N
SP
SP
2. Enter
for YES - tone will sound or
1 1
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0

3.1.5 Talk Time

This programming sequence sets the maximum time allowed for conversation when the entry system places a call to the
resident. The talk time can be set from 1 second up to 255 seconds (4 minutes, 15 seconds) and is entered as a three-digit
number in step 3. The talk time set here DOES NOT affect the telephone numbers that are programmed under directory codes
0, 00, 000, 0000 and 1, 01, 001, 0001. The talk time for these two directory code sets are factory set to the maximum. Phone
numbers programmed under these directory codes should be reserved for management or emergency phone numbers that
generally require longer conversations.
Factory setting for talk time = 060 (60 seconds).
OPER
OPER
TUV
TUV
1. Press
0 0
8 8
2. Enter the three-digit talk time in seconds (001-255), then press
(Example: 1 second - enter 001, 20 seconds - enter 020 etc.)
OPER
OPER
3. Press
together to end this programming sequence (beeeeeep).
0 0
1802-065-D-10-14
If you make a mistake while programming, press
and enter your four-digit MASTER CODE
and enter your four-digit MASTER CODE
ABC
ABC
2 2
and enter your four-digit MASTER CODE
OPER
OPER
for NO - tone will not sound, then press
0 0
and enter your four-digit MASTER CODE
? ?
? ?
? ?
SP
SP
(beep) for multiple systems.
1 1
? ?
? ?
? ?
(beep) to set Relay 2 strike time.
(beep).
? ?
? ?
? ?
? ?
? ?
? ?
(beep).
OPER
OPER
keys at the same time
0 0
? ?
(beep).
? ?
(beep).
? ?
(beep).
(beep).
? ?
(beep).