2.3 Telephone Entry System Wiring and Adjustments

LCD Display Contrast
Adjust
See 2.3.3
Switch Input 2 -
A switch closure across these
terminals activates Relay 2 for
its programmed strike time or
dials a preprogrammed phone
number.
See section 3.1.8 Switch Input
Feature.
Note: LCD display must be
removed to access this terminal
with 1802EPD models.
Master Code Switch
See 2.3.4
Click Sensitivity
Adjust
See 2.3.2
Microphone Adjust
See 2.3.1
Feedback Adjust
See 2.3.1
Speaker Adjust
See 2.3.1
Tone On/Off Jumper
See 2.3.1
Ring Pin Jumper
See 2.3.5
Handset/ Hands Free
Jumper
See 2.3.6
PHONE
Central Office
Phone Line Input
touch tone, loop start
"PHONE"
"PHONE"
Wire Size
Distance
24 AWG
Up to 800 ft
22 AWG
Up to 1600 ft
Earth Ground
Wiring MUST be twisted and
See section 2.1.3.
completely isolated from ground.
See section 2.1.4.
"PSW" Switch Input 1 -
See section 1.6 for Postal lock connection.
A switch closure across these terminals activates
Relay 1 for its programmed strike time or dials a
preprogrammed phone number.
See section 3.1.8 Switch Input Feature.
16
CONTRAST
DOORKING 1862-010
ON
MASTER
CODE
OFF
CLCK
SENSE
KEYPAD
3 2 1
MIC VOL
FEEDBACK
3 2 1
SPK
3 2 1
VOL
TONE
ON
HF
RING
TONE
HS
OFF
Main Terminal
CGND
PSW
MICG
MIC
SPKR
COM
"CGND"
Gate Control
Gate Operator
To a Relay Input
Gate Operator
is wired to
Normally Open
(NO) relay
input.
NO
NC
C
BAT
C
NC
NO
16AC
16AC
"NO" - Normally Open (NO)
"NC" - Normally Closed (NC)
"C" - Common (C)
Red (Pos)
"BAT" - 12 VDC Back-Up Battery Input
Black (Neg)
Back-up battery power for the telephone entry system.
Door Control
To a
Relay Input
Lock Power
UL listed
"C" - Common (C)
"NC" - Normally Closed (NC)
"NO" - Normally Open (NO)
Wire Size
Power Input
20 VA
18 AWG
16.5 VDC, 20 VA power.
16 AWG
See section 2.1.1.
Relay Input 1
Door
Lock
Power for electric strike or magnetic
lock is NOT provided by the system.
Use separate UL listed power supply.
Relay Input 2
Distance
Up to 100 ft
Up to 200 ft
Door Locks
Electric strike is wired
to Normally Open (NO)
relay input.
Magnetic lock is wired to
the Normally Closed (NC)
relay input.
1802-065-D-10-14